logo

Guangzhou Xingjin Fire Equipment Co.,Ltd. info@xingjin-fire.com 86--18011936582

Guangzhou Xingjin Fire Equipment Co.,Ltd. Perfil de la empresa
productos
En casa > productos > De sistema del gas inerte extinción de incendios > Custom FM200 Fire System Piping Network with Corrosion-Resistant Pipes for Enclosed Space Safety

Custom FM200 Fire System Piping Network with Corrosion-Resistant Pipes for Enclosed Space Safety

Detalles del producto

Lugar de origen: Cantón, China

Nombre de la marca: XINGJIN

Certificación: CCC,CAC,ROHS

Número de modelo: IG541

Condiciones de pago y envío

Cantidad de orden mínima: Sistema de 10 conjuntos

Precio: Pricing based on quantity

Detalles de empaquetado: Caja exterior de madera o madera contrachapada con bolsa de burbujas o papel

Tiempo de entrega: 15-20 días

Condiciones de pago: T/T, LC/C

Capacidad de la fuente: 30000 juegos/mes

Obtenga el mejor precio
Detalles del producto
Resaltar:
Ingredientes principales:
Nitrógeno (N2), Argón (Ar), Dióxido de Carbono (CO2)
Temperatura ambiente operativa:
0~50 ℃
Presión de trabajo nominal (20 ℃):
15MPa
Presión de trabajo máxima (20 ℃):
17.2MPA
Volumen de la botella de almacenamiento:
80/90L
Volumen de llenado de la botella de almacenamiento (20 ℃):
12/13,5m3
Voltaje de funcionamiento del sistema:
220 V CA, 24 V CC
Método de inicio del sistema:
Eléctrico Automático, Eléctrico Manual, Arranque de Emergencia Mecánico
Presión de alivio de seguridad (MPa):
23±1,15
La rosca de salida de la válvula del contenedor.:
M30 por uno.5
Ingredientes principales:
Nitrógeno (N2), Argón (Ar), Dióxido de Carbono (CO2)
Temperatura ambiente operativa:
0~50 ℃
Presión de trabajo nominal (20 ℃):
15MPa
Presión de trabajo máxima (20 ℃):
17.2MPA
Volumen de la botella de almacenamiento:
80/90L
Volumen de llenado de la botella de almacenamiento (20 ℃):
12/13,5m3
Voltaje de funcionamiento del sistema:
220 V CA, 24 V CC
Método de inicio del sistema:
Eléctrico Automático, Eléctrico Manual, Arranque de Emergencia Mecánico
Presión de alivio de seguridad (MPa):
23±1,15
La rosca de salida de la válvula del contenedor.:
M30 por uno.5
Descripción del producto

IG541 Mixed Gas Automatic Fire Suppression System


Product Introduction:
  IG541 mixed gas extinguishing agent is a colorless, odorless, non-toxic, and non-conductive pure "green" compressed gas. It is composed of atmospheric gases—nitrogen, argon, and carbon dioxide—with abundant raw materials. During the fire extinguishing process, it does not obstruct people's vision and does not produce temperature differences or corrosive decomposition products. The release of the extinguishing agent simply returns the gases to their natural state. It has no ozone depletion potential (ODP), does not produce a "greenhouse effect," and does not produce chemical substances that damage the atmosphere. It does not cause the toxicity problems associated with halogenated alkanes and their alternative extinguishing agents during the fire extinguishing process. It is an ideal extinguishing agent suitable for places where people frequently work.

Custom FM200 Fire System Piping Network with Corrosion-Resistant Pipes for Enclosed Space Safety 0
 

Composition and quality indicators of the mixed gas:

Main ingredients Nitrogen(N2) Argon gas(Ar) Carbon dioxide(CO2)
Purity requirements for each component >99.9% >99.9% >99.5%
Moisture content requirements for each component <5ppm <4ppm <10ppm
Oxygen content requirements for each component <3ppm <3ppm <10ppm

 

 

Extinguishing Principle of the Extinguishing Agent:
 

The extinguishing principle of the IG541 gas mixture is primarily to reduce the oxygen concentration (below 15%) to inhibit combustion and thus extinguish the fire. It can extinguish Class A surface fires, Class B flammable liquid fires, and fires involving energized electrical equipment in enclosed spaces using total flooding methods.



 

 

Custom FM200 Fire System Piping Network with Corrosion-Resistant Pipes for Enclosed Space Safety 1
 

Product features:
MULTI ZONE PROTECTION
  The conveying distance can reach over 150m
  According to usage requirements, the lG541 fire extinguishing system can form a unit independentsystem and a combined distribution system, using a fully submerged method to achieve fireprotection for a single protection zone and multiple protection zones, The system has high storagepressure, and the distance from the steel cylinder to the nozzle can reach over 150M

CLEAN GAS
  Colorless and non-toxicNot damaging equipment
  Good electrical insulation, no harm to personnel at the sceneof a fire, lt can be started in automatically, manually ormechanical emergency mode according to the needs of different occaslon.
 

Technical Parameters:
IG541 FIRE EXTINGUISHING SYSTEMMIXED GAS EXTINGUISHING AGENT
  The lG541 mixed gas fire extinguishing system generally consists of a mixtureof 52% nitrogen40% gas, and 8% carbon dioxide, with a lower cost thanHFC-227ea, After spraying, it will not cause a sharp drop in temperature in theprotective zone, and will not cause any harm to precision equipment and otherprecious properties
 

Operating ambient temperature: ℃ 0~50

Work

 

Pressure

Nominal work pressure(20℃)MPa 15
Maximum working pressure(20℃)MPa 17.2
Minimum working pressure(20℃)MPa 13.6
 Storage bottle volumeL 80 90
Storage bottle filling capacity(20℃)m3 12 13.5
System operating voltage 220V AC,24V DC
System startup mode Electrical automatic, electrical manual, mechanical emergency start

Fire extinguishing

Concentration

Extinguish Class A solid surface fires 28.1%
Extinguish Class B liquid fires 33.8%

 

Design concentration

Extinguish Class A solid surface fires 36.5%
Extinguish Class B liquid fires 43.9%
The design concentration in a workplace where people are present 37.5~43%
 
Extinguishing Principle of the Extinguishing Agent

The extinguishing principle of the IG541 gas mixture is primarily to reduce the oxygen concentration (below 15%) to inhibit combustion and thus extinguish the fire. It can extinguish Class A surface fires, Class B flammable liquid fires, and fires involving energized electrical equipment in enclosed spaces using total flooding methods.

 

Application Locations:

Computer rooms, communication equipment rooms, transformer rooms, electrical switch and distribution rooms, generator rooms, oil immersion tanks, drying equipment, paint booths, electrical instrument rooms, control centers, libraries and archives, and cultural relic storage facilities, etc.


Custom FM200 Fire System Piping Network with Corrosion-Resistant Pipes for Enclosed Space Safety 2


Why choose us?
 

 

Custom FM200 Fire System Piping Network with Corrosion-Resistant Pipes for Enclosed Space Safety 3