logo

Guangzhou Xingjin Fire Equipment Co.,Ltd. info@xingjin-fire.com 86--18011936582

Guangzhou Xingjin Fire Equipment Co.,Ltd. Perfil de la empresa
productos
En casa > productos > Sistema de supresión del gas FM200 > Modular FM200 Pipe Network System / Integrated Inert Gas Protection for Telecom Sites

Modular FM200 Pipe Network System / Integrated Inert Gas Protection for Telecom Sites

Detalles del producto

Lugar de origen: GUANGZHOU,CHINA

Nombre de la marca: XINGJIN

Certificación: CCC,ROHS,CAC

Número de modelo: 4.2Mpa/5.6Mpa

Condiciones de pago y envío

Cantidad de orden mínima: Sistema de 10 conjuntos

Precio: USD480-520/set

Detalles de empaquetado: Caja exterior de madera o madera contrachapada con bolsa de burbujas o papel

Tiempo de entrega: 15-20 días

Condiciones de pago: T/T, L/C

Capacidad de la fuente: 30000 juegos/mes

Obtenga el mejor precio
Detalles del producto
Resaltar:

FM200 modular pipe system

,

FM200 gas suppression for telecom

,

integrated inert gas protection system

Presión de relleno:
4.2Mpa/5.6Mpa
Escala de región protectora para una zona:
Área: la zona única máxima es de 800 m². Volumen: la zona única máxima es de 3600 m³.
Tiempo de pulverización:
≤10S
Densidad de llenado:
≤950kg/m3,≤1080kg/m3
Fuerza:
CC 24 V/1,6 A.
Presión de nitrógeno de la conducción:
6.0 ± 1.0MPA (20 ℃)
Condición del espacio de reserva para el contenedor:
temperatura: -10~50°C, humedad relativa: ≤97%
Presión máxima de trabajo:
5.3Mpa/8.0Mpa
Presión de trabajo mínima:
4.2 MPa/4.6 MPa
Presión de relleno:
4.2Mpa/5.6Mpa
Escala de región protectora para una zona:
Área: la zona única máxima es de 800 m². Volumen: la zona única máxima es de 3600 m³.
Tiempo de pulverización:
≤10S
Densidad de llenado:
≤950kg/m3,≤1080kg/m3
Fuerza:
CC 24 V/1,6 A.
Presión de nitrógeno de la conducción:
6.0 ± 1.0MPA (20 ℃)
Condición del espacio de reserva para el contenedor:
temperatura: -10~50°C, humedad relativa: ≤97%
Presión máxima de trabajo:
5.3Mpa/8.0Mpa
Presión de trabajo mínima:
4.2 MPa/4.6 MPa
Descripción del producto

FM200 Pipe Network Fire Suppression System

Product Overview

  The FM200 Pipe Network Fire Suppression System is a clean agent fire protection solution widely used in commercial and industrial applications. Using HFC-227ea (FM200) as the extinguishing agent, the system distributes fire suppression through a centralized cylinder bank and pipe network.

It is ideal for protecting data centers, commercial buildings, power facilities, and critical assets. With features such as fast discharge (≤10 seconds), no residue, non-conductivity, and automatic control, it minimizes downtime and protects valuable equipment, making it one of the most cost-effective fire suppression systems for commercial projects.


Key Commercial Advantages

  • Cost-Effective for Large Projects:A single system can protect multiple areas, reducing equipment investment and installation costs.

  • Fast Response to Minimize Loss:≤ 10 seconds of spraying, reducing the risk of equipment damage and business interruption

  • No Residue – Safe for Equipment:After extinguishing the fire, there is no need for cleaning, thus avoiding secondary losses.

  • Flexible Control Modes:Support automatic, electrical manual and mechanical emergency start-up

  • OEM & Custom Solutions Available:Support for bottle group configuration, pressure rating, and system design customization


Working Principle

When a fire occurs, detectors send signals to the control panel:

  1. Audible and visual alarms activate
  2. Time delay allows personnel evacuation
  3. Solenoid valve opens
  4. Driving gas activates the system
  5. Cylinder and selector valves open
  6. FM200 agent flows through piping
  7. Nozzles discharge agent into hazard area

The system quickly achieves total flooding fire suppression.


Applications

Widely used in commercial and industrial sectors:

  • Data Centers / Server Rooms
  • Office Buildings
  • Banks & Financial Institutions
  • Telecom Facilities
  • Power Distribution Rooms
  • Medical Equipment Rooms
  • Museums & Libraries
  • Industrial Facilities

Modular FM200 Pipe Network System / Integrated Inert Gas Protection for Telecom Sites 0

Technical Specifications

Item Parameter
Extinguishing Agent FM200 (HFC-227ea)
Discharge Time ≤10s
Filling Pressure 4.2MPa / 5.6MPa
Max Protection Area 800 m²
Max Protection Volume 3600 m³
Control Mode Automatic / Manual / Emergency
Operating Temperature -10℃ ~ 50℃
Start Power Supply DC24V



System Components

  • FM200 Cylinder Bank
  • Driving Gas Cylinders
  • Cylinder Valves
  • Selector Valves (for multi-zone control)
  • Pipe Network System
  • Discharge Nozzles
  • Fire Detection & Control System

Modular FM200 Pipe Network System / Integrated Inert Gas Protection for Telecom Sites 1

Why Choose Us

  • 15+ years manufacturing experience
  • OEM / ODM service available
  • Complete system solution provider
  • Professional engineering support
  • Fast delivery & global export experience



Request a Quote

We provide:

  • System design support
  • Configuration recommendations
  • Competitive pricing
  • Technical documentation